Pipe systems for data centers:
Future-proofed infrastructure for the cooling backbone

Key Facts

Cooling is essential to operation

Data centers continuously generate heat that must be reliably removed. Powerful cooling is therefore one of the central technical requirements of data center infrastructure.

Figures from the Uptime Institute illustrate the economic impact that outages can have: for 57 percent of operators surveyed, their most recent major outage cost more than $100,000. One in five major outages even cost more than $1 million. These figures highlight the significant operational and economic importance of reliable operation.[1]

57%
of operators report that their most recent major outage cost more than $100,000.[1]
20%
put the cost at over $1 million.[1]

The cooling backbone connects the cooling infrastructure

A key part of the cooling system is the external chilled water circuit, often referred to as the cooling backbone. It connects the data center to cooling towers, dry coolers, or chiller systems via supply and return lines. These lines can run over large dimensions and long distances, and are often laid underground outside the buildings.

Advantages of PE

Advantages of PE pipes for the cooling backbone
PE pipe systems are used in data centers thanks to a wide range of benefits. The material offers favorable properties for transporting chilled water.

PE is corrosion-resistant, contributing to the longevity and operational reliability of the pipe system. No additional measures are required to protect against external corrosion.

Welded joints create a leak-tight, longitudinally force-locked pipe system with high operational reliability.

The smooth inner pipe surface minimizes flow resistance and supports an energy-efficient chilled water supply.

PE pipes up to OD 1600 enable the realization of a high-performance chilled water infrastructure. At the same time, the flexibility of PE makes it easier to adapt to the respective route.

Monitored pipe systems

Monitoring provides a decisive information advantage

Monitored pipe systems create transparency along the buried route. Integrated sensor and monitoring technology detects leaks as well as relevant changes and impacts on the pipeline at an early stage. This extends the cooling backbone from a pure transport medium into an intelligent monitoring and early warning system.

Continuous monitoring reveals anomalies before their consequences become visible at the surface or affect operation. In the event of an external impact, the system issues an early warning. This allows measures to be taken before the carrier pipe is damaged, chilled water leaks out, or cooling performance is impaired.

If damage or a leak has already occurred, its location can be pinpointed to the meter. This avoids extensive search efforts along the route. Excavation and repair work can be focused precisely on the affected section.
This gain in information and time delivers a direct operational and economic benefit: the faster an event is detected and located, the more targeted the response can be. Search and repair times are shortened, potential limitations to cooling performance are minimized, and the costs associated with the event are significantly reduced.

Continuous monitoring

Leaks and relevant changes are detected at an early stage.

Early warning function

External impacts are made visible before water leakage occurs, wherever possible.

Pinpoint damage location

The affected section of pipeline can be precisely determined.

Targeted repairs

Search efforts, excavation, and repair are concentrated on the damaged section.

Lower follow-up costs

Shorter response and repair times can reduce limitations to cooling performance and the associated costs.

Currently planning a data center project?

We are happy to support you in planning your cooling backbone. Early involvement allows the capabilities of monitored pipe systems to be fully leveraged and project-specific services to be integrated as needed.
Contact us now
Sven Brickwedde
Product Management

egeplast solutions for data centers at a glance

egeplast offers a range of complementary pipe systems for the cooling backbone, each with a different scope of functionality
Unlock All Downloads
Thank you for your interest! Please complete the fields to instantly access this and all future downloads from our site.